Articles

PITT-CHAR XP

Epoxy Intumescent Coating

  • Superior fir & corrosion protection
  • Unique flexibility
  • Superior mechanical resistance
  • Suitable for cryogenic exposure
  • Complies with international fire standards
 
Volume Solids% (ISO 3233) 100
Dry Film Thickness (µm) dependent
Theoretical Coverage (m²/l) 0.25 (at 5mm/0.2)
Mixing Ratio (Volume) 2.33:1
Packing Size (kg) 70
Thinner /Cleaner Thinner T-47/Amercoat 920
Data Sheets Technical Data
  MSDS Resin | MSDS Cure

STEELGUARD FM 549

Thin Film Intumescent Coating

  • Thin film solvent based intumescent
  • Tested to international fire test standards
  • Up to 2 hours fire protection of structural steel
  • Off-site or on-site application
  • Up to 1.5 mm dry film thickness application in a single coat
  • Rapid job completion
  • For use in C1 & C2 internal environments - no sealer coat required for dry internal C1 service conditions ( ISO 12944)
 
Volume Solids% (ISO 3233) 68 +-3
Dry Film Thickness (µm) 250 - 1500
Theoretical Coverage (m²/l) 2.72 (250 µm) 0.45 (1500 µm)
Mixing Ratio (Volume)  
Packing Size (ltr) 20
Thinner /Cleaner Amercoat 65
Data Sheets Technical Data
  MSDS Resin | MSDS Cure

STEELGUARD FM 550

Thin Film Intumescent Coating

  • Thin film solvent based intumescent
  • Tested to international fire test standards
  • Up to 2 hours fire protection of structural steel
  • Off-site or on-site application
  • Up to 1.5 mm dry film thickness application in a single coat
  • Rapid job completion
  • For use in C1,C2,C3 & C2 internal environments - no sealer coat required for dry internal C1 service conditions ( ISO 12944)
 
Volume Solids% (ISO 3233) 68 +-3
Dry Film Thickness (µm) 250 - 1500
Theoretical Coverage (m²/l) 2.72 (250 µm) 0.45 (1500 µm)
Mixing Ratio (Volume)  
Packing Size (ltr) 20
Thinner /Cleaner Amercoat 65
Data Sheets Technical Data
  MSDS Resin | MSDS Cure

STEELGUARD 560

Thin Film Intumescent Coating

  • Fast drying solvent based thin film intumescent
  • Rapid drying providing reduced times to handling
  • Tested to internal fire test standards
  • Up to 2 hours fire protection of structural steel
  • Off-site or on-site application
  • Up to 1.0 mm dry film thickness application in a single coat
  • For use in C1,C2,C3 & C2 internal environments - no sealer coat required for dry internal C1 service conditions ( ISO 12944)
 
Volume Solids% (ISO 3233) 68 +-3
Dry Film Thickness (µm) 250 - 1000
Theoretical Coverage (m²/l) 2.72 (250 µm) 0..68 (1000 µm)
Mixing Ratio (Volume)  
Packing Size (ltr) 20
Thinner /Cleaner Amercoat 65
Data Sheets Technical Data
  MSDS Resin | MSDS Cure

STEELGUARD 564

Thin Film Intumescent Coating

  • Fast drying solvent based thin film intumescent
  • Rapid drying providing reduced times to handling
  • 120 minute fire protection on structural I beams
  • Off-site or on-site application
  • Up to 1.0 mm dry film thickness application in a single coat
  • For use in C1,C2,C3 & C2 internal environments - no sealer coat required for dry internal C1 service conditions ( ISO 12944)
 
Volume Solids% (ISO 3233) 75 +-3
Dry Film Thickness (µm) 200 - 1000
Theoretical Coverage (m²/l) 1.07 (700 µm)
Mixing Ratio (Volume)  
Packing Size (ltr) 20
Thinner /Cleaner Amercoat 65
Data Sheets Technical Data
  MSDS Resin | MSDS Cure

STEELGUARD 2458

Single Pack Acrylic Finish

  • EPA compliant (1998) as a finish for Steelguard Intumescent coatings
  • High build
  • Suitable for external exposure
  • Single pack material
  • Good colour retention
 
Volume Solids% (ISO 3233) 45 +- 2
Dry Film Thickness (µm) 50 - 125
Theoretical Coverage (m²/l) 6.0 (75 µm)
Mixing Ratio (Volume)  
Packing Size (ltr) 20
Thinner /Cleaner Amercoat 65
Data Sheets Technical Data
  MSDS Resin | MSDS Cure